{"id":2835,"date":"2026-02-05T01:34:54","date_gmt":"2026-02-05T01:34:54","guid":{"rendered":"https:\/\/test.geo-tester.com\/products\/rdvt-01-vacutainer-drawing-volume-tester\/"},"modified":"2026-02-05T01:34:54","modified_gmt":"2026-02-05T01:34:54","slug":"rdvt-01-vacutainer-drawing-volume-tester","status":"publish","type":"products","link":"https:\/\/test.geo-tester.com\/tr\/products\/rdvt-01-vacutainer-drawing-volume-tester.html","title":{"rendered":"RDVT-01 Vacutainer \u00c7ekme Hacmi Test Cihaz\u0131"},"content":{"rendered":"<div>\n<h2><strong>1. RDVT-01 \u00c7iziminin Tan\u0131t\u0131m\u0131\u00a0<a class=\"aahaf6o\" title=\"hacim test cihaz\u0131\" href=\"https:\/\/test.geo-tester.com\/tr\/products\/clrt-01-carbon-dioxide-volume-tester.html\/\">hacim test cihaz\u0131<\/a><\/strong><\/h2>\n<\/div>\n<p>RDVT-01 \u00c7ekme Hacmi Test Cihaz\u0131, vacutainerlerin (kan alma t\u00fcpleri) pompalama hacmi i\u00e7in ge\u00e7erlidir ve belirli bir rak\u0131m\u0131 do\u011fru bir \u015fekilde sim\u00fcle edebilir ve vacutainer performans\u0131n\u0131n analizi i\u00e7in ger\u00e7ek bir ortam olu\u015fturabilir.<\/p>\n<p>&nbsp;<\/p>\n<h2><strong>2. Neden bir RDVT-01 \u00c7izim Hacmi Test Cihaz\u0131na ihtiyac\u0131n\u0131z var?<\/strong><\/h2>\n<p>Y\u00fcksek rak\u0131ml\u0131 b\u00f6lgelerde vacutainer (kan alma t\u00fcpleri) kullanmak, y\u00fcksek rak\u0131mlarda atmosferik bas\u0131n\u00e7 ve gazlar\u0131n k\u0131smi bas\u0131nc\u0131ndaki de\u011fi\u015fiklikler nedeniyle baz\u0131 zorluklar yaratabilir.<\/p>\n<p>Y\u00fcksek rak\u0131mlarda atmosferik bas\u0131n\u00e7 azal\u0131r. Bu durum, \u00f6zellikle kan\u0131 t\u00fcpe \u00e7ekmek i\u00e7in bas\u0131n\u00e7 farklar\u0131na dayanan vacutainerlerin dolumunu etkileyebilir. Daha d\u00fc\u015f\u00fck atmosferik bas\u0131n\u00e7, kan\u0131n daha yava\u015f veya eksik al\u0131nmas\u0131na neden olabilir.<\/p>\n<p>Atmosferik bas\u0131n\u00e7taki de\u011fi\u015fiklikler kandaki gazlar\u0131n k\u0131smi bas\u0131nc\u0131n\u0131 etkileyerek kan bile\u015fiminin de\u011fi\u015fmesine yol a\u00e7abilir. Bu durum, kan gazlar\u0131ndaki de\u011fi\u015fimlere duyarl\u0131 testleri etkileyebilir.<\/p>\n<p>\u00dcreticiler, farkl\u0131 rak\u0131mlardaki ko\u015fullar\u0131 sim\u00fcle etmek i\u00e7in vakutainerlerini bas\u0131n\u00e7 testine tabi tutabilir. Bu, d\u00fc\u015f\u00fck atmosferik bas\u0131nc\u0131n kan alma s\u00fcreci \u00fczerindeki etkisinin de\u011ferlendirilmesine yard\u0131mc\u0131 olur.<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-medium wp-image-282\" src=\"https:\/\/test.geo-tester.com\/wp-content\/uploads\/2025\/12\/RDVT-01-Vacutainer-Drawing-Volume-Tester-300x300.jpg\" alt=\"RDVT-01 Vacutainer \u00c7ekme Hacmi Test Cihaz\u0131\" width=\"300\" height=\"300\" srcset=\"https:\/\/test.geo-tester.com\/wp-content\/uploads\/2025\/12\/RDVT-01-Vacutainer-Drawing-Volume-Tester-300x300.jpg 300w, https:\/\/test.geo-tester.com\/wp-content\/uploads\/2025\/12\/RDVT-01-Vacutainer-Drawing-Volume-Tester-150x150.jpg 150w, https:\/\/test.geo-tester.com\/wp-content\/uploads\/2025\/12\/RDVT-01-Vacutainer-Drawing-Volume-Tester-768x768.jpg 768w, https:\/\/test.geo-tester.com\/wp-content\/uploads\/2025\/12\/RDVT-01-Vacutainer-Drawing-Volume-Tester-600x600.jpg 600w, https:\/\/test.geo-tester.com\/wp-content\/uploads\/2025\/12\/RDVT-01-Vacutainer-Drawing-Volume-Tester-100x100.jpg 100w, https:\/\/test.geo-tester.com\/wp-content\/uploads\/2025\/12\/RDVT-01-Vacutainer-Drawing-Volume-Tester.jpg 800w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/p>\n<h2><strong>3. RDVT-01 \u00c7izim Hacmi Test Cihaz\u0131n\u0131n Avantajlar\u0131<\/strong><\/h2>\n<p>1.RDVT-01, istikrarl\u0131 end\u00fcstriyel d\u00fczeyde kontrol i\u00e7in bir Programlanabilir Mant\u0131k Denetleyicisi (PLC) ve rahat kullan\u0131m i\u00e7in kullan\u0131c\u0131 dostu bir \u0130nsan-Makine Aray\u00fcz\u00fc (HMI) dokunmatik ekran ile donat\u0131lm\u0131\u015ft\u0131r.<\/p>\n<p>2. Kullan\u0131\u015fl\u0131 bir dijital giri\u015f sunar ve s\u0131v\u0131 seviyesi de\u011fi\u015ftik\u00e7e ayarlayarak tank i\u00e7inde tutarl\u0131 bir bas\u0131n\u00e7 seviyesini otomatik olarak korur. Bu \u00f6zellik, test s\u00fcrecinin hassasiyetini ve do\u011frulu\u011funu sa\u011flar.<\/p>\n<p>3. Sistem, kullan\u0131c\u0131 i\u00e7in hem yerden hem de ek maliyetlerden etkili bir \u015fekilde tasarruf sa\u011flayan entegre bir vakum pompas\u0131 i\u00e7erir. Bu kompakt tasar\u0131m, \u00e7al\u0131\u015fma s\u0131ras\u0131nda kullan\u0131c\u0131 rahatl\u0131\u011f\u0131n\u0131 ve verimlili\u011fini art\u0131r\u0131r.<\/p>\n<h3><\/h3>\n<h2><strong>4. RDVT-01 \u00c7izim Hacmi Test Cihaz\u0131n\u0131n Test Prensibi<\/strong><\/h2>\n<p>Vakum tank\u0131n\u0131n i\u00e7indeki bas\u0131n\u00e7la tutarl\u0131 hale getirmek i\u00e7in test vacutainer'\u0131n\u0131 test sisteminin delinme b\u00f6lgesine yerle\u015ftirin; daha sonra vacutainer'\u0131n kullan\u0131ld\u0131\u011f\u0131 alan\u0131n rak\u0131m\u0131na g\u00f6re i\u00e7inde farkl\u0131 bas\u0131n\u00e7 de\u011ferleri olu\u015fturmas\u0131n\u0131 sa\u011flay\u0131n.<\/p>\n<p>1 dakika bekleyin. Ard\u0131ndan bo\u015f vacutainer ile doldurulduktan sonraki vacutainer aras\u0131ndaki a\u011f\u0131rl\u0131k de\u011fi\u015fimini \u00f6l\u00e7\u00fcn.  Aradaki fark \u00e7ekme hacmi olarak kabul edilir.<\/p>\n<p>&nbsp;<\/p>\n<h2><strong>5.Uygulama:\u00a0<\/strong><\/h2>\n<p>Vacutainer, kan alma t\u00fcp\u00fc.<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-medium wp-image-283\" src=\"https:\/\/test.geo-tester.com\/wp-content\/uploads\/2025\/12\/RDVT-01-Vacutainer-Drawing-Volume-Tester2-300x300.jpg\" alt=\"RDVT-01 Vacutainer \u00c7ekme Hacmi Test Cihaz\u0131\" width=\"300\" height=\"300\" srcset=\"https:\/\/test.geo-tester.com\/wp-content\/uploads\/2025\/12\/RDVT-01-Vacutainer-Drawing-Volume-Tester2-300x300.jpg 300w, https:\/\/test.geo-tester.com\/wp-content\/uploads\/2025\/12\/RDVT-01-Vacutainer-Drawing-Volume-Tester2-150x150.jpg 150w, https:\/\/test.geo-tester.com\/wp-content\/uploads\/2025\/12\/RDVT-01-Vacutainer-Drawing-Volume-Tester2-768x768.jpg 768w, https:\/\/test.geo-tester.com\/wp-content\/uploads\/2025\/12\/RDVT-01-Vacutainer-Drawing-Volume-Tester2-600x600.jpg 600w, https:\/\/test.geo-tester.com\/wp-content\/uploads\/2025\/12\/RDVT-01-Vacutainer-Drawing-Volume-Tester2-100x100.jpg 100w, https:\/\/test.geo-tester.com\/wp-content\/uploads\/2025\/12\/RDVT-01-Vacutainer-Drawing-Volume-Tester2.jpg 800w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/p>\n<h2><strong>6. \u00d6zellikler<\/strong><\/h2>\n<div class=\"table\">\n<table>\n<tbody>\n<tr>\n<td>Vakum Aral\u0131\u011f\u0131<\/td>\n<td>0~-45 Kpa<\/p>\n<p>(5000m rak\u0131ma benzer)<\/td>\n<\/tr>\n<tr>\n<td>Do\u011fruluk<\/td>\n<td>0,1 Kpa<\/td>\n<\/tr>\n<tr>\n<td>Kontrol<\/td>\n<td>PLC ve insan makine aray\u00fcz\u00fc<\/td>\n<\/tr>\n<tr>\n<td>G\u00fc\u00e7<\/td>\n<td>AC 110~220V 50\/60Hz<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>&nbsp;<\/p>\n<h2><strong>7.Standartlar:<\/strong><\/h2>\n<p>YY 0314, EN 14820, ISO 6710<\/p>\n<p>&nbsp;<\/p>\n<h2><strong>8.Konfig\u00fcrasyon:<\/strong><\/h2>\n<p>a) Standart konfig\u00fcrasyon: RDVT-01 \u00c7ekme Hacmi Test Cihaz\u0131, vakum tank\u0131, numune tutucu, sigortalar, k\u0131lavuz, kalibrasyon sertifikas\u0131, g\u00fc\u00e7 kablosu.<\/p>\n<p>b) \u0130ste\u011fe ba\u011fl\u0131 yap\u0131land\u0131rma: Standart Olmayan oda, RS 232 Portu, COM Hatt\u0131, Yaz\u0131l\u0131m<\/p>\n<p>&nbsp;<\/p>\n<p class=\"aahaf6o\">Bu \u00fcr\u00fcn hakk\u0131nda daha fazla bilgi almak isterseniz, l\u00fctfen bizimle ileti\u015fime ge\u00e7mekten \u00e7ekinmeyin. Sizin i\u00e7in di\u011fer pop\u00fcler \u00fcr\u00fcnleri tavsiye ederiz:\u00a0<a class=\"aahaf6o\" title=\"karboni\u0307k gaz hacmi\u0307 test tablosu\" href=\"https:\/\/test.geo-tester.com\/tr\/products\/clrt-01-carbon-dioxide-volume-tester.html\/\">karboni\u0307k gaz hacmi\u0307 test tablosu<\/a><\/p>","protected":false},"excerpt":{"rendered":"<p>1. RDVT-01 \u00c7ekme hacmi test cihaz\u0131n\u0131n tan\u0131t\u0131m\u0131 RDVT-01 \u00c7ekme Hacmi Test Cihaz\u0131, vacutainerlerin (kan alma t\u00fcpleri) pompalama hacmi i\u00e7in ge\u00e7erlidir ve belirli bir rak\u0131m\u0131 do\u011fru bir \u015fekilde sim\u00fcle edebilir ve vacutainer performans\u0131n\u0131n analizi i\u00e7in ger\u00e7ek bir ortam olu\u015fturabilir.   2. Neden bir RDVT-01 \u00c7ekme Hacmi Test Cihaz\u0131na ihtiyac\u0131n\u0131z var? Y\u00fcksek rak\u0131ml\u0131 b\u00f6lgelerde vacutainer (kan alma t\u00fcpleri) kullanmak [...]<\/p>","protected":false},"featured_media":0,"parent":0,"template":"","meta":{"_acf_changed":false},"products-categories":[1301],"productstags":[1439,1440,1441],"class_list":["post-2835","products","type-products","status-publish","hentry","products-categories-medical-device-tester","productstags-carbonic-gas-volume-testing-chart","productstags-co2-gas-volume-tester","productstags-gas-volume-tester"],"acf":[],"_links":{"self":[{"href":"https:\/\/test.geo-tester.com\/tr\/wp-json\/wp\/v2\/products\/2835","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/test.geo-tester.com\/tr\/wp-json\/wp\/v2\/products"}],"about":[{"href":"https:\/\/test.geo-tester.com\/tr\/wp-json\/wp\/v2\/types\/products"}],"version-history":[{"count":0,"href":"https:\/\/test.geo-tester.com\/tr\/wp-json\/wp\/v2\/products\/2835\/revisions"}],"wp:attachment":[{"href":"https:\/\/test.geo-tester.com\/tr\/wp-json\/wp\/v2\/media?parent=2835"}],"wp:term":[{"taxonomy":"products-categories","embeddable":true,"href":"https:\/\/test.geo-tester.com\/tr\/wp-json\/wp\/v2\/products-categories?post=2835"},{"taxonomy":"productstags","embeddable":true,"href":"https:\/\/test.geo-tester.com\/tr\/wp-json\/wp\/v2\/productstags?post=2835"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}